• <fieldset id="6cuue"><input id="6cuue"></input></fieldset>
  • Hotline:18857165617 Ms. Yang
    Popular: Thermal desorption instrumentation ,Headspace sampler Purge and trapExtraction and distillationAtmospheric preconcentratorGas sampler and dynamic dilutor
    News

    Company dynamics

    Home > News > Company dynamics

    ATDS-20A Max Automatic Thermal Desorption Instrument

    source:中儀宇盛   date:2020-04-29 16:17:00   click:
      

    ATDS-20A Max Automatic Thermal Desorption Instrument


     


    1. Purpose and application scope


    ATDS-20A Max automatic thermal desorption instrument is a sample pretreatment device, used with GC, GCMS, the minimum detection concentration of volatile organic compounds in the detection environment can reach ppb level. This device can meet the following standards:


    1. "HJ / 644-2013 Ambient Air Determination of Volatile Organic Compounds, Adsorption Tube Sampling-Thermal Desorption Gas Chromatography-Mass Spectrometry";


    2. "HJ / T400-2007 Sampling and determination method of volatile organic compounds and aldehydes and ketones in vehicles";


    3. "GB / T18883-2002 Indoor Air Quality Standard";


    4. "HJ / 583-2010 Ambient Air Determination of Benzene Series Solid Adsorption / Thermal Desorption-Gas Chromatography";


    5. "GB / 50325-2010 Civil Building Engineering Indoor Environmental Pollution Control Code", etc.


    6. "HJ734-2014 fixed pollution source waste volatile organic compounds determination solid phase adsorption / thermal desorption-gas chromatography" and so on.


     


    2. Instrument characteristics and main functions


    1. A new generation of upgraded products, brand-new fashion design, internal structure optimization and reorganization, transmission and positioning are more accurate and reliable.


    2. Adopt a new type of electronic pressure sensor, the pressure status is displayed accurately and in real time;


    3. Can run up to 20 samples automatically, without personnel on duty;


    4. Power-on self-test, fault alarm and prompt;


    5. Seven-inch capacitive touch screen control, human-computer interaction is more intuitive and comfortable:


    (1) Method parameter setting, real-time animation display working status and running time;


    (2) The desorption zone, sampling valve, sample transfer tube and secondary desorption zone are all heated and temperature controlled separately;


    (3) The GC and chromatographic data processing workstation can be started synchronously, and the device can also be started by an external program;


    6. This machine comes with standard sample simulation function, which can make the working curve more easily through thermal desorption instrument;


    7. Through time programming, automatically realize the functions of desorption, purge adsorption, re-desorption, sample injection, backflush cleaning, etc .;


    8. Low temperature secondary desorption adopts electronic refrigeration and second-order thermal desorption process to ensure narrow chromatographic peak shape;


    9. The sample transfer tube and sampling valve have automatic backflushing function to avoid cross contamination of different samples;


    10. In order to support imported GC and GCMS, it is more convenient and accurate to use. This instrument is also equipped with special interfaces for various imported instruments, which can be connected to all types of GC and GCMS at home and abroad;


    11. For active substance analysis, elastic quartz tube can be used as sample transfer tube;


     


    Three, technical indicators


    1. Desorption 1 temperature control range:


       Room temperature—400 ℃, set in increments of 1 ℃;


    2. Temperature control range of valve sampling system:


       Room temperature—220 ℃, set in increments of 1 ℃;


    3. Temperature control range of sample transfer pipeline:


       Room temperature—240 ℃, set in increments of 1 ℃


      (For operation safety, the temperature control of the transmission pipeline uses low voltage power supply);


    4. Desorption 2 temperature control range:


       Room temperature—400 ℃, set in increments of 1 ℃;


      (Heating rate> 2000 ℃ / min)


    5. Cold trap temperature control range:


       -35 ℃ —50 ℃ set in increments of 1 ℃


      (Using the most advanced electronic refrigeration device, no liquid nitrogen refrigeration is required)


    6. Temperature control accuracy: <± 0.1 ℃;


    7. Temperature control gradient: <± 0.1 ℃;


    8. Sample position: 20


    9. Desorption recovery rate:> 98% (related to components);


    10. Backwash cleaning flow: 0 ~ 100ml / min (continuously adjustable);


    11. Simulated sampling flow: 100ml / min;


    12. Instrument size: 487x425x506mm3;


    13. Instrument weight: about 40kg.


    About Us
    Company Profile
    Appointment interview
    corporate culture
    Video Center
    News
    Company dynamics
    Common problem
    Product
    PURGE AND TRAP SERIES
    Headspace sampler
    Thermal desorption
    Gas generator
    Consumables and accessories
    Contact us
    Add:Building 13,Zhongnan High-tech Electronic InformationIndustrial Park,Yanjiao Sanhe Langfang,Hebei,China.
    EMAIL:info@bjzyyskj.com.cn
    Tel:+86-010-61598028 18857165617 Ms. Yang
    Fax:010-61598028-108
    WeChat

    Scan
    Copyright ? 2018 Beijing Zhongyi Yusheng Technology Co., Ltd 京ICP備10046828號-2
    主站蜘蛛池模板: 口国产成人高清在线播放| 成人自拍视频在线观看| 亚洲精品成人a在线观看| 国产成人精品动图| 国产成人免费一区二区三区| 国产成人免费一区二区三区| 免费国产成人午夜私人影视| 亚洲国产精品成人久久| 久久久久免费看成人影片| 欧美日韩成人在线| 国产成人亚洲精品无码av大片| 四虎影视成人永久免费观看视频| 久久久久成人精品免费播放动漫| 日本成人不卡视频| 四虎高清成人永久免费影院| 欧美成人久久久| 国产成人无码免费看片软件| 5g影院欧美成人免费| 成人免费无码大片a毛片软件| 四虎永久成人免费影院域名| 欧美成人久久久| 久久成人免费播放网站| 成人免费在线播放| 色欲欲WWW成人网站| 亚洲精品午夜国产va久久成人| 国产成人AV三级在线观看按摩| 欧美日韩国产成人精品| 国产成人免费片在线观看| 成人毛片一区二区| 七次郎成人免费线路视频| 国产成人无码精品久久久露脸| 成人美女黄网站色大色下载| 色五月婷婷成人网| 亚洲av午夜成人片精品网站| 国产成人小视频| 国产日韩欧美成人| 成人午夜在线播放| 成人免费视频网站| 成人中文字幕一区二区三区| 日韩国产欧美成人一区二区影院| WWW夜片内射视频日韩精品成人|